Showing results: 16 - 30 of 70 items found.
-
Neutronics Manufacturing Co.
1. Test as per International standards NMC insulating oil testers are fully automatic micro controller based system,completely self-contained,compact and portable giving smooth variable test voltage from 0 to 60, 80, or 100 kV for testing the dielectric strength of insulating oil in accordance with all international standards like IEC156/IS6792/ASTM D 1816/ASTM D877/ UNE 21 specifications.2. Auto mode NMC insulating oil testers are fully automatic type.1) IEC-156, IS6792, ASTM D 877, ASTM D 1816, UNE 21.2) Withstand Test A3) Withstand Test B4) 5 Minute Test5) User defined3. 100 Test results storage capacity NMC insulating oil testers has a storage capacity of 100 test results which can be recalled and printed.4. LCD display NMC insulating oil testers use LCD for easy readability of the BDV test results.5. Built in printer The printer used is a thermal paper print outs.The paper rolls can be easily installed by any person.6. User Friendly RS 232 Interface RS 232 interface is very easy to use to communicate stored data which can be saved in text format.7. Safety protection Safety interlocks are provided on the test chamber.Zero interlock protection to ensure operator safety.8. Accurate Performance The kit not only has all basic functions of an insulating oil tester but also has unique features that are seldom seen in similar products. For e.g. PROOF test A, PROOF test B, 5 Minntes test, LCD to display all test data.It ensures high work efficiency and reliability in any tough environment.
-
-
AS-023A -
Chongqing Assen Power Equipment Co., Ltd
AS-023A Series High Quality Intelligent Transformer Oil Dielectric Strength Tester is specially designed for testing dielectric strength (Breakdown Voltage) of transformer oil. The breakdown voltage (dielectric strength) is one of the most important parameters of transformer oil, it is a rule of the voltage withstand. The value of breakdown voltage (dielectric strength) indicates whether the oil contains water, impurity and electric particles, and you’ll know the oil value via the breakdown voltage (dielectric strength).
-
-
-
GC2010D -
Chongqing Kailian Yongrun Industrial Co.,Ltd.
Transformer uses oil as coolant and insulator. Gases are formed within the transformer oil due to natural aging, faults from oxidation, vaporization, oil breakdown, electrolytic action or insulation decomposition. Because the transformer oil bathes each internal component, dissolved gases in the transformer oil contain lots of diagnostic information. Meanwhile, the transformer is very expensive to be replaced, so monitoring these gases is very important to know the current quality of transformer or even when the transformer should be removed from service before failure. Presence of each gas composition and its concentration indicates possible failure of transformer.
-
-
Sigma 702ET -
Biolin Scientific
The Sigma 702ET Transformer Oil Analyzer has been specifically designed to guide the user through the measurement of interfacial tension of transformer oil according to relevant standards.
-
R.R.Transformers & Equipments
RR-OIL TEST SET also known as OIL BDV KIT is an equipment-designed and produced to test the ELECTRICAL STREGTH of Liquid Insulating Materials such as Transformer Oil, Capacitor Oil etc. The test set carries out test on these materials as per Indian Standard Specification IS 6792. This Oil Test Set is essential for Transformer & Switchgear Manufacturers, also for oil filtration units.
-
Haomai Electric Power Automation Co.,Ltd.
The laser-based photoacoustic spectroscopy transformer oil and gas online monitoring system developed has a lot of advantages comparing with the traditional oil chromatography oil and gas online monitoring equipment and wide light source photoacoustic spectroscopy transformer oil and gas monitoring system. Please check the following figure to see the details:
-
-
R.R.Transformers & Equipments
RR manufactures Transformer for Oil Test Set / Oil BDV Set. These are available in→ 25-0-25 KV→ 30-0-30 KV→ 40-0-40 KV→ 50-0-50 KV→ 60-0-60KV→ Higher ranges availableThese transformers are available in various models to suit various needs and budgets. We Specialize in manufacturing LOW WEIGHT TRANSFORMERS for AUTOMATIC OIL TEST SET MICROPROCESORS.
-
CP TC12 -
OMICRON electronics
The CP TC12 oil test cell is for determining the relative permittivity, the dissipation factor and the power factor of insulating liquids such as transformer oil.
-
7000 -
Cambridge Instruments & Engineering Co.
Ideal for speedy and accurate testing of Breakdown / withstand test of transformer and circuit breaker oil, in accordancewith IS 6792 : 1992 for oil testing.
-
KVIO-80 -
KV Hipot Power Test Equipment Co.,Ltd
Automatic Insulation Oil Breakdown Tester Is Used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool etc.